VPX Plus Backplane Cabling System

Meritec offers a compatible cabling system that provides endless possibilities for accessing and expanding the basic VPX backplane. Bring all VITA46 and Open VPX I/O out of your VPX backplane utilizing SATA, SAS, Serial Rapid I/O, Infiband, Ethernet and Mil-38999 connectors. This system and its I/O capabilities are designed for full bandwidth test and deployment.


The Meritec's VPXPlus also allows ultimate flexibility when either cabling daughter-card position to daughter-card position, point-to-point, or when incorporating cable I/O from the backplane. This utility recognized the need for laboratory development experimentation and for ultimately deployable product having certain unique functions.

Meritec VPX+

Product Details

  • FEATURES & BENEFITS

    • Short (3U) and Long (6U) housings – can be used independently on front and rear of backplane
    • Housing kits designed for both 1.0″ and 0.8″ center-center spacing
    • Deployment rails provide additional support
    • Rail is positioned between latch & polyamide overmold
    • Wafers have PCBs designed for minimum skew
    • Wafers are over-molded for mechanical integrity
    • Compatible with VITA 46 / OpenVPX mechanicals

    Wafers

    • PCBs designed for minimum skew

    • Color coded for identification

    • Over-molded for mechanical  integrity


  • SPECIFICATIONS

    Housing & Hardware

    • Made of Nickel plated zinc alloy

    • Polarized for wafers

    • Designed for 0.8” center-center spacing

    • Threaded for stainless steel deployment rails

    • Rails are mounted to housing with captive screws

    • Provides additional support; rail is positioned between latch & polyamide overmold

    • Ensures wafer retention in high high-vibration environment


    12” Wafer – Wafer Cable Specs

    • Cable: 30 gauge Stranded Coax

    • Insertion Loss: <2.5dB up to 5GHz

    • Return Loss: <10dB up to 5GHz

    • Connector Impedance: 100 +/-  10% at 100ps rise time (20 - 80%)

    • Within Pair Skew: <3ps ft

    • Time Domain Crosstalk: <4% at  40ps rise time (-20 to +80%) from multiple aggressors

    • Integrated snap locks to align stacked wafers

    • 4 Types of Cable Assemblies

    Ultra Thin Pipe − 1 wafer to 1 wafer w/ 2 DP connected

    Thin Pipe − 2 wafers to 2 wafers w/ 4 DP connected

    Fat Pipe − 4 wafers to 4 wafers w/ 8 DP connected

    Double Fat Pipe − 8 wafers to 8 wafers w/ 16 DP connected


    Fat Pipe – CX4 Cable Assembly Specs

    • Cable: 30 gauge Stranded Coax

    • Insertion Loss: <5.0dB up to 5GHz

    • Return Loss: <10dB up to 5GHz

    • Connector Impedance: 100 +/- 10% at 100ps rise time (20 - 80%)

    • Within Pair Skew: <3ps ft

    • Time Domain Crosstalk: <4% at 40ps rise time (-20 to +80%) from multiple aggressors